Sharma, Vikash and Puri, NitinK and Mulchandani, Ashok and -, Rajesh (2016) Platinum nanoparticles-single-walled carbon nanotubes hybrid based chemiresistive sensor array for myoglobin detection. Materials Research Express, 3 (3). ISSN 2053-1591
PDF
- Published Version
Restricted to Registered users only Download (899Kb) | Request a copy |
Abstract
We examined the potential of platinum nanoparticles (PtNP) modified single-walled carbon nanotube (SWNT) hybrid chemiresistive sensor for detection of antigen myoglobin (Mb) in phosphate buffer saline. Protein antibody, Ab-Mb, was covalently immobilized through site specific binding on PtNP attached over SWNT. A concentration-dependent change in the source-drain current of the hybrid device was observed in the range of 0.1-1000 ng ml(-1). The hybrid device response fitted well with the Hill-Langmuir equation with a maximum response of 111.14% and low dissociation constant value (K-d = 19.98 ng ml(-1)), indicating high protein antigen binding affinity at hybrid nanostructure.
Item Type: | Article |
---|---|
Additional Information: | Copyright for this article belongs to M/s IOP Publishing. |
Subjects: | Materials Science |
Divisions: | UNSPECIFIED |
Depositing User: | Dr. Rajpal Walke |
Date Deposited: | 12 Apr 2018 07:07 |
Last Modified: | 12 Apr 2018 07:07 |
URI: | http://npl.csircentral.net/id/eprint/2330 |
Actions (login required)